Double-clad fiber amplifier, calculation of cladding mode RP Fiber Power
This is another example of a double-clad fiber amplifier. Different from the above example, we consider all cladding modes and use the built-in mode solution method. According to the refractive index distribution, the numerical aperture of the core, and the conditions of the cladding pumping mode, the mode characteristics are calculated. For simplicity, set the […]